GANGPUEnvironmental Technology

Industrial Dust Collection

Blast Furnace Cast House Dust Collection System

Offline pulse baghouse with capture hoods on the cast house and slag runner, replacing an undersized collector that could not hold the emission limit during tapping.

Baghouse dust collection system installed at a steel plant blast furnace cast house

Original condition

The problem on site

The existing collector was sized for a smaller furnace campaign. During tapping, dust escaped through the cast house roof, bag blinding raised resistance above 2,400 Pa and the fan could not hold the required negative pressure. The plant also faced a short shutdown window for the retrofit.

Engineering approach

What we designed and built

  1. 01Re-measured dust source points at the taphole, runner and slag pit, then redesigned capture hoods and duct routing to shorten the run and balance the pressure drop.
  2. 02Sized a new 8-chamber offline pulse baghouse at 6,400 m² filter area with cloth velocity below 1.0 m/min for abrasive cast house dust.
  3. 03Selected PTFE membrane filter bags with anti-static treatment and hardened hoppers to extend service life under abrasive load.
  4. 04Installed a VFD controlled induced draft fan with pressure feedback so the system follows the tapping cycle instead of running at fixed speed.
  5. 05Pre-assembled chambers in the factory and used a modular lifting plan to complete the installation inside the scheduled shutdown.

Measured results

Before and after commissioning

Values recorded on this project under its own operating condition. Results at another plant depend on fuel, material, load profile and the local standard in force.

Before and after measurements for Blast Furnace Cast House Dust Collection System
ItemBeforeAfter
Handled air volume180,000 m³/h (insufficient capture)320,000 m³/h with new hood design
Outlet dust concentrationAbove site limit during tappingStable low level, verified by site CEMS
System resistance2,400 Pa with blinded bags1,450 Pa after cleaning system upgrade
Bag lifeAbout 8 monthsOver 24 months with PTFE membrane media

Outcome

How the system runs now

After commissioning, the cast house roof no longer shows visible emission during tapping, system resistance stays around 1,450 Pa and the fan runs at reduced speed for most of the cycle. Emission values are recorded by the plant CEMS and remain within the site limit, subject to local regulation and actual operating condition.

Site records

Fabrication, erection and commissioning

Baghouse dust collection system installed at a steel plant blast furnace cast house
Baghouse dust collection system installed at a steel plant blast furnace cast house
Capture hood and ductwork installed above a blast furnace cast house
Capture hood and ductwork installed above a blast furnace cast house
Baghouse hopper with rotary airlock discharger at a steel plant
Baghouse hopper with rotary airlock discharger at a steel plant
Engineer commissioning the dust collection control panel on site
Engineer commissioning the dust collection control panel on site